It really depends how much power/current you are switching. If you are switching 1A with a beefy heatsink FET, the time spent in the linear region is short enough it shouldn't be a problem. If you are switching 50A though it then you might have a problem. Depending on how that gate divider is set up, you could still potentially damage the gate of the FET when shorting it to ground to discharge it if I understand how its hooked up correctly.
Ideally you would use some kind of FET driver with a voltage source (e.g. linear regulator) to turn on and off the gate plus the gate resistor.