this post was submitted on 11 Oct 2023
9 points (100.0% liked)

Debian operating system

2718 readers
1 users here now

Debian is a free operating system (OS) for your computer. An operating system is the set of basic programs and utilities that make your computer run. Debian provides more than a pure OS: it comes with over 59000 packages, precompiled software bundled up in a nice format for easy installation on your machine.

founded 4 years ago
MODERATORS
 

I have an annoying problem on my server and google has been of no help. I have two drives mirrored for the OS through mdadm, and I recently replaced them with larger versions through the normal process of replacing one at a time and letting the new drive re-sync, then growing the raids in place. Everything is working as expected, with the exception of systemd... It is filling my logs with messages of timing out while trying to locate both of the old drives that no longer exist. Mdadm itself is perfectly happy with the new storage space and has reported no issues, and since this is a server I can't just blindly reboot it to get systemd to shut the hell up.

So what's the solution here? What can I do to make this error message go away? Thanks.

[Update] Thanks to everyone who made suggestions below, it looks like I finally found the solution in systemctl daemon-reload however there is a lot of other great info provided to help with troubleshooting. I'm still trying to learn the systemd stuff so this has all been greatly appreciated!

you are viewing a single comment's thread
view the rest of the comments
[–] Shdwdrgn@mander.xyz 3 points 1 year ago

Status reports "State: degraded" but then doesn't say WHAT is degraded and shows no other errors (and /proc/mdstat shows no errors). Trying systemctl by itself does show an error from logrotated but that seems unrelated?

I do see the drive errors again in journalctl but I don't see anything helpful here... maybe you'll see something? These errors get repeated for both of the old drives about every 30 minutes, and I believe the UUIDs are for the old drives since they don't match any existing drive.

Oct 11 07:10:40 Juno systemd[1]: Timed out waiting for device ST500LM021-1KJ152 5.

Oct 11 07:10:40 Juno systemd[1]: Dependency failed for /dev/disk/by-uuid/286e26b0-603a-43b2-bc0f-30853998d5ab.

Oct 11 07:10:40 Juno systemd[1]: dev-disk-by\x2duuid-286e26b0\x2d603a\x2d43b2\x2dbc0f\x2d30853998d5ab.swap: Job dev-disk-by\x2duuid-286e26b0\x2d603a\x2d43b2\x2dbc0f\x2d30853998d5ab.swap/start failed with result 'dependency'.

Oct 11 07:10:40 Juno systemd[1]: dev-disk-by\x2duuid-286e26b0\x2d603a\x2d43b2\x2dbc0f\x2d30853998d5ab.device: Job dev-disk-by\x2duuid-286e26b0\x2d603a\x2d43b2\x2dbc0f\x2d30853998d5ab.device/start failed with result 'timeout'.

Oct 11 07:10:40 Juno systemd[1]: dev-disk-by\x2duuid-96b0277b\x2dcf9d\x2d4360\x2dbf90\x2d691166cff52b.device: Job dev-disk-by\x2duuid-96b0277b\x2dcf9d\x2d4360\x2dbf90\x2d691166cff52b.device/start timed out.